Spatial profiles of the reduced electric field, mean electron energy and space charge density along the symmetry axis at four characteristic times during the transient glow phase. The table contains the axial position in the first column, and the reduced electric field, mean electron energy and space charge density for each time in the following columns.
column 1: 'z [m]'
column 2: 'reduced electric field [Td] at 51.1 microseconds'
column 3: 'mean electron energy [eV] at 51.1 microseconds'
column 4: 'space charge density [C m^-3] at 51.1 microseconds'
column 5: 'reduced electric field [Td] at 51.6 microseconds'
column 6: 'mean electron energy [eV] at 51.6 microseconds'
column 7: 'space charge density [C m^-3] at 51.6 microseconds'
column 8: 'reduced electric field [Td] at 51.8 microseconds'
column 9: 'mean electron energy [eV] at 51.8 microseconds'
column 10: 'space charge density [C m^-3] at 51.8 microseconds'
column 11: 'reduced electric field [Td] at 52.0 microseconds'
column 12: 'mean electron energy [eV] at 52.0 microseconds'
column 13: 'space charge density [C m^-3] at 52.0 microseconds'